Kunming Duobao Cable Co., Ltd.
Main products:Overhead Stranded Wire, Plastic Insulated Control Cables, High and Low Voltage Power Cables, Overhead Insulated Cables, Electrical Equipment Cable
Products
Contact Us
  • Contact Person : Mr. Zheng XiaoBin
  • Company Name : Kunming Duobao Cable Co., Ltd.
  • Tel : 86-871-67181262
  • Fax : 86-871-67181262
  • Address : Yunnan,kunming,Luoyang Zhen Wangjia Community,Kunming Economic Development Area,Kunming, Yunnan, China
  • Country/Region : China
  • Zip : 650000

PVC insulation no jacket wire

PVC insulation no jacket wire
Product Detailed
PVC insulated wire BV/BVR/BVV/BVVB/BLVVB/BV-105 indoor cable, civil cable, house wiring

  PVC insulation no jacket wire

I,Structure Picture   II,Main Specification of Product

1,Product Name:

PVC insulation no jacket wire

2,Product standard:

GB5023.3-1997(idt IEC227-3:1985); JB8734.3-1998; JB8734.4-1998;

3,Type of cable:

227IEC01(BV); 227IEC02(RV); 227IEC05(BV); 227IEC06(RV);227IEC07(BV-90); 227IEC08(RV-90);BVR; BV; AV; AV-90; AVR; AVR-90;H05V-K; HO5V-R; H05V-U; H07V-K; H07V-R; HO7V-U;

4,Cable specification:

227IEC01(BV)450/750V ,227IEC02(RV)450/750V: 1.5~120mm2; 227IEC05(BV)300/500V 0.5~1.0mm2;227IEC06(RV)300/500V 0.5~1.0mm2;227IEC07(BV-90)300/500V 0.5~2.5mm2 ;227IEC08(RV-90)300/500V 0.5~2.5mm2;BV 300/500V 0.75~1.0mm2;BVR 450/750V  2.5~70mm2;AV,AV-90,AVR,AVR-90 300/300V 0.2~0.4mm2;

5,Operating temperature:

0°C~40°C(Max. allowed temperature of conductor is 70°C);

6,Type of conductor:

Table1~Table4;

7,Material of conductor:

Anaerobic soft copper wires;

8,Material of insulation:

BV,RV,BVR,AV,AVR:High quality lead-free PVC soft insulation;BV-90,RV-90,AV-90,AVR-90:High quality lead-free and heat-proof PVC soft insulation;

9,Color of core insulation:

Random;

10,Burning test:

According with IEC60332-1 single vertical burning requirement;

11,DC resistance of conductor at 20°C:

Comply with GB/T3956-1997(IEC228:1978) and JB8734.3-4-1998;

12,Insulation resistance at 70°C:

Comply with GB5023.3-1997(idt IEC227-3:1985) and JB8734.3.4-1998;

13,Finished product voltage proof test:

300/300V:1.5KV(AC)/5min,no breakdown;300/500V:2.0KV(AC)/5min,no breakdown;450/750V:2.5KV(AC)/5min,no breakdown;

14,3C certificate No.:

2003010105082949,2004010105119784,2004010105119789;

15,Lead free environment protection performance:Products are fully complied with the requirement of heavy metal quantity in EU RoHS, Testing data is as follow:

Sequence NumberElementUnitRoHS standardActual inspected data of cable
1Pdppm<10002
2Hgppm<10002
3Cr+6ppm<10002
4Cdppm<1002
5PBBppm<10005
6PBDEppm<10005
III,Product parameter Table1
Type Voltage calssSection(mm2)Type of conductorThickness of insulation(mm)Insulation resistance at 70°C(MΩ·km)Conductor DC resistance at 20°C(Ω/km)Size(mm)Reference Weight(kg/km)
227IEC01(BV)450/750V1.510.7≥0.011≤12.12.8519.9
1.520.7≥0.010≤12.12.9820.9
2.510.8≥0.010≤7.413.4531.5
2.520.8≥0.009≤7.413.7033.7
4.010.8≥0.0085≤4.613.9046.5
4.020.8≥0.0077≤4.614.2049.1
6.010.8≥0.0070≤3.084.4066.1
6.020.8≥0.0065≤3.084.8068.6
1011.0≥0.0070≤1.835.70113.5
1021.0≥0.0065≤1.836.10115.8
1621.0≥0.0050≤1.157.20175.1
2521.2≥0.0050≤0.7278.90277.5
3521.2≥0.0040≤0.52410.10372.2
5021.4≥0.0045≤0.38711.90499.5
7021.4≥0.0035≤0.26813.70703.5
9521.6≥0.0035≤0.19316.00972.1
227IEC02(RV)450/750V1.550.7≥0.010≤13.33.0020.9
2.550.8≥0.009≤7.983.7033.0
450.8≥0.007≤4.954.3048.9
650.8≥0.006≤3.304.8569.4
227IEC05(BV)300/500V0.510.6≥0.015≤36.01.988.1
0.7510.6≥0.012≤24.52.2010.7
1.010.6≥0.011≤18.12.3511.5
227IEC06(RV)300/500V0.550.6≥0.013≤39.02.158.8
0.7550.6≥0.011≤26.02.4011.9
1.050.6≥0.010≤19.52.5614.5
IV,BVR product parameter: Table2
Type Voltage calssSection(mm2)Type of conductor(mm)Thickness of insulation(mm)Insulation resistance at 70°C(MΩ·km)Conductor DC resistance at 20°C(Ω/km)Size(mm)Reference Weight(kg/km)
BVR450/750V2.519/0.410.8≥0.011≤7.413.7033.6
4.019/0.520.8≥0.009≤4.614.3049.2
6.019/0.640.8≥0.0084≤3.084.8572.9
1049/0.521.0≥0.0072≤1.836.60123.4
1649/0.641.0≥0.0062≤1.157.70178.7
2598/0.581.2≥0.0058≤0.7279.90295.9
35133/0.581.2≥0.0052≤0.52411.00388.6
50133/0.681.4≥0.0051≤0.38712.80533.4
70189/0.681.4≥0.0045≤0.26815.30746.5
V,BV,AV,AVR products parameter: Table3
Type Voltage calssSection(mm2)Type of conductor(mm)Thickness of insulation(mm)Insulation resistance at 70°C(MΩ·km)Conductor DC resistance at 20°C(Ω/km)Size(mm)Reference Weight(kg/km)
BV300/500V0.757/0.370.6≥0.014≤24.52.3513.5
1.07/0.430.6≥0.013≤18.12.5014.4
AV300/300V0.21/0.500.4≥0.015≤92.31.33.3
0.31/0.500.4≥0.014≤64.11.404.3
0.41/0.700.4≥0.012≤47.11.505.3
AVR300/300V0.212/0.150.4≥0.014≤92.31.453.7
0.316/0.150.5≥0.014≤69.21.705.2
0.423/0.150.5≥0.012≤48.21.906.9
VI,90°C heat proof wire parameter: Table4
Type Voltage calssSection(mm2)Type of conductor(mm)Thickness of insulation(mm)Insulation resistance at 90°C(MΩ·km)Conductor DC resistance at 20°C(Ω/km)Size(mm)Reference Weight(kg/km)
AV-90300/300V0.21/0.500.4≥0.015≤92.31.33.3
0.31/0.500.4≥0.014≤64.11.404.3
0.41/0.700.4≥0.012≤47.11.505.3
AVR-90300/300V0.212/0.150.4≥0.014≤92.31.453.7
0.316/0.150.5≥0.014≤69.21.705.2
0.423/0.150.5≥0.012≤48.21.906.9
227IEC07(BV-90)300/500V0.51/0.800.6≥0.015≤36.01.988.1
0.751/0.970.6≥0.013≤24.52.2010.7
1.01/1.130.6≥0.012≤18.12.3513.5
1.51/1.380.7≥0.011≤12.12.8520.1
2.51/1.780.8≥0.009≤7.413.4531.5
227IEC08(RV-90)300/500 V0.516/0.200.6≥0.013≤39.02.158.8

PVC insulation no jacket wire